AISC K1.5 Warning

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 12/28/2016 6:56:10 PM

 Applies To 
 Product:Ram Connection
First Affected Version:11.00.00.177
 Found in Version:11.00.00.177
Fixed in Version:11.00.01.208
Environment:All
 Area: Design; Report
 Issue #:386503

Problem Description

In some connections, a warning is produced stating,

[Warning] "Plate strength must be less than the HSS wall strength (Ref. AISC 360-05 Section K1.5).

This should not be reported due to the note in that AISC section which states, "For bracing connections to HSS columns, where a load is applied by a longitudinal plate at an angle to the HSS axis, the connection design will be governed by the force component perpendicular to the HSS axis (see Section K1.4b)." In other words, the limit state for K1.4b (which is checked) would occur before the limit state in K1.5. If Section K1.4b is checked, then the check in Section K1.5 does not need to be applied.

Reason

Affects all implementations. 

Solution

The warning is removed in version 11.00.01.208 and after.

Tags: Fist 11.00.00, design, 11.00.01, RAM Connection, AISC 360, known issue, defect, Report, warning