Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 12/28/2016 5:57:49 PM
Applies To | |||
Product: | Ram Connection | ||
First Affected Version: | 11.00.00.164 | ||
Found in Version: | 11.00.00.177 | ||
Fixed in Version: | 11.00.01.208 | ||
Environment: | All | ||
Area: | Graphics | ||
Issue #: | 368974 |
Problem Description
In the 3D graphic (and in the bolt gage) the double angles connecting the gusset to the column are shown with 1/4" gap spacing regardless the thickness of the gusset.
Reason
It's a bit complicated because the gusset plate above and below the beam could be different thickness meaning that the larger plate thickness would govern (and shims could be required).
Solution
With version 11.00.01.028 the graphics are adjusted so that the double angles spacing is based on the beam web thickness. Where the gusset plate thickness is significantly thicker than the beam web the angles will still be too closely spaced.
Tags: First 11.00.00, graphics, 11.00.01, RAM Connection, known issue, defect