Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 12/23/2016 5:14:23 PM
Applies To | |||
Product(s): | RAM Elements; Ram Connection | ||
First Affected Version: | 12.00.00.00 | ||
Found in Version: | 12.01.00.29 | ||
Fixed in Version: | |||
Environment: | All | ||
Area: | General | ||
Issue #: | 380624 |
Problem
Frame Types for Braced Frames used in the Connection Module are not available.
Only moment frame types are included for frame type selection in the main program (input under Spreadsheet - Members - Steel Design - AISC - Seismic Provisions - Frame:
Specific braced frame types, OCBF or SCBF, can be assigned in the Connection Pad, but these are not saved with the connection joint and has to be reset each time the connection is reviewed.
Previously recorded as TR 70797
Solution
Assign the frame type within the connection pad and then print results.
See Also
Troubleshooting Errors when Assigning Connections
Tags: know issue, Active, enhancement, RAM Elements, GENERAL, RAM Connection, Migrated, SELECTsupport