Problem Description
STAAD.Pro is not able to read the external user table files and is generating errors like
*** ERROR : FILE NOT FOUND C:\...\...
**ERROR- IN READING MEMBER PROPERTIES. CHECK DATA FORMAT CAREFULLY.
.
Steps to Reproduce
Run analysis on a model which refers to an external user table file.
Above errors appear during analysis.
.
Workaround
Ensure that the upt file is in the same folder as the STAAD.Pro model.
Provide the full path name to the file. For example instead of specifying
START USER TABLE
TABLE 1 wf1.txt
END
specify the input as shown next
START USER TABLE
TABLE 1 C:\Model_folder\wf1.txt
END
Solution
The issue is addressed in 20.07.11.50
See Also
Tags: First 20.07.11.45, 20.07.11.50, STAAD.Pro, upt, known issue, defect, external user table