Current Revision posted to RAM | STAAD Wiki by Sye on 11/18/2016 1:34:32 AM
Applies To | |||
Product: | STAAD.Pro | ||
First Affected Version: | 20.07.11.70 | ||
Found in Version: | 20.07.11.70 | ||
Released in Version: | 20.07.11.82 | ||
Environment: | All | ||
Area: | Design | ||
Subarea: | AISC 360-05/10 | ||
Issue #: | 447990 |
Problem Description
Double Channel Front to Front cannot be designed as per AISC Unified 360-05 and 360-10 codes. An ERROR: MEMBER DESIGN FAILED FOR MEMBER xx is reported
Steps to Reproduce
- Try to design a double channel front to front section using AISC 360-05/10
- An error message mentioned above appears in the analysis output file
Workaround
Such sections can be designed in older versions of STAAD.Pro like SS5 ( 20.07.10.65). So use an older version to design these sections.
Solution
This is addressed in 20.07.11.82
See Also