AISC 360 F7 Design of Built-up Box Shapes with Slender Webs

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 11/2/2016 10:02:45 PM

 Applies To 
 Product:RAM Steel
First Affected Version:15.03.00.00
 Found in Version:15.03.00.00
Released in Version:15.04.00.00
 Area: Design
 Issue #:564955

Problem Description

Built-up box shapes with slender webs were unintentionally designed and incorrect capacities were output by the program. 

Reason

AISC 360 Section F7 applies to built-up box shapes with compact or noncompact webs only. It does not apply to box shaped sections with slender webs. When the web was slender, the program should have output a slenderness warning and reported no design.

Solution

The issue will be resolved in the release after v15.03.00. In the meantime, the user should use caution designing slender web built up shapes in the Ram Steel beam module.

Tags: slender, design, 15.04.00, RAM Structural System, First 15.03.00, AISC 360, known issue, defect, Deflection Check, Unconservative, RAM Steel