Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

RAM Structural System Results Cleared After Import into RAM Concept

$
0
0
Revision 3 posted to RAM | STAAD Wiki by Seth Guthrie on 10/26/2016 6:26:21 PM

 Applies To 
 Product:Ram Concept 
First Affected Version:
 Found in Version:06.00.01.06
Fixed in Version:
Environment:All
 Area: File, Import/Export
Subarea:N/A
 Issue #:386307

Problem Description

RAM Structural System results in each module are cleared when the model is imported into a standalone RAM Concept .cpt file. The results are cleared even if no changes or a file-save are done in RAM Concept.

Solution

The problem does not occur when RAM Concept is launched directly from RAM Manager. The analysis results remain after information is imported, the model is analyzed, and reactions are exported back to RAM Structural System. 

Tags: analysis, Active, import, RAM Structural System, RAM Concept, results, defect