ACI 318 Effective Depth Coupling Beam Design

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 10/19/2016 7:18:50 PM

 Product(s):RAM Concrete Shear Wall
 First Affected Version:
Found in Version:15.00.00.00
Fixed in VersionN/A
 Environment:N/A
 Area:Design
 Subarea:N/A
 Defect Number:355889

Problem Description

When calculating shear capacity of coupling beams, the program uses an effective depth of 0.8 x the beam height. The effective depth should be calculated using a strain compatibility analysis and represent the distance from the extreme tension fiber to the centroid of the tension reinforcement.

Reason

The use of 0.8xbeam depth follows from ACI 318-11 11.9.4. This is appropriate for walls but may not be appropriate for coupling beams.

Solution

In a future release, the effective depth will be calculated as the distance to the centroid of the tension reinforcement.

Tags: design, Coupling Beam, RAM Structural System, ACI 318, known issue, defect, Ram Concrete, Shear Wall