Problem Description
Members subject to flexure only and designed using the Eurocode were assigned to an incorrect section class. Members subject to axial load only or a combination of axial and flexure were correctly classified.
Reason
Members under pure flexure were given a classification of 1 when they could have been a higher class.
Solution
The issue will be resolved in the release after v15.03.00.