Steel column design crashes with assigned sizes

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 10/7/2016 11:25:12 PM

 Applies To 
 Product:Ram Steel Column
First Affected Version:14.07.00.00
 Found in Version:14.07.01.01
Fixed in Version:15.02.00.00
 Area: Design
 Issue #:246733

Problem Description

Crash, MFC application has stopped working, error during Steel Column design-all routine in specific models with assigned steel column sizes.

Reason

The problem is with the index values for some deck types (hollow core and precast types) being NULL.

Solution

Problem solved in version 15.02.00.00.

In the prior version, using optimized column sizes or resetting all the design criteria was a way to avoid the problem in those models that had uninitialized deck properties. 

Tags: design, 15.02.00, Column, RAM Structural System, crash, MFC, known issue, defect, RAM Steel