Defect Description
AS 4100-98: The controlling interaction reported in the View Update dialog box for columns under compression and weak axis bending was not consistent with the governing interaction shown in the detailed column report.
While columns subjected to axial and weak axis bending were correctly designed and the governing interaction shown in the column design report was also correct, the controlling interaction displayed in the View Update dialog was incorrect. Also the reference for the controlling interaction shown in the Summary Report was incorrect and also ontrolling clause in the summary report is incorrect (shows 8.4.5.1 instead of 8.4.2.2).
Steps to Reproduce
AS4100-98 Steel Column design with compression and weak-axis shear.
Workaround
Problem corrected in version 15.04.00.00. In earlier versions use the detailed design report.