Revision 1 posted to RAM | STAAD Wiki by Seth Guthrie on 10/5/2016 11:27:06 PM
Applies To | |||
Product: | RAM Steel | ||
First Affected Version: | |||
Found in Version: | 15.03.00.00 | ||
Fixed in Version: | 15.04.00.00 | ||
Area: | Design | ||
Issue #: | 540806 / 562996 |
Problem Description
Round HSS with slender webs exceeding the limit set in Section F8 were unintentionally designed and wrong capacities indicated in the report.
Reason
Round HSS with slender webs exceeding the limit in F8 were incorrectly designed and reports showed incorrect results. The program should have indicated a warning message to the user and shown no design.
Solution
The issue will be resolved in the release after v15.03.00.
Tags: design, Column, RAM Structural System, known issue, RAM Steel