Incorrect Building Story Shear and Frame Story Shear Results for Dynamic Load Cases

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 9/9/2016 8:47:23 PM

 Applies To 
 Product:RAM Frame Analysis
First Affected Version:15.03.00.00
 Found in Version:15.03.00.00
Fixed in Version:
 Area: Analysis
 Issue #:537872

Problem Description

Incorrect Building Story Shear and Frame Story Shears are reported when dynamic load cases are analyzed with gravity load cases only. Correct results are obtained when only dynamic load cases are analyzed or when the dynamic loads are analyzed with both gravity and static seismic load cases. The issue affects models with semirigid diaphragms and two-way decks.

Reason

The program is not processing results for gravity columns and walls correctly.

Solution

The issue will be resolved in the release after v15.03.00. In the meantime, analyze dynamic load cases with gravity load cases and static seismic load cases.