Current Revision posted to RAM | STAAD Wiki by Sye on 7/28/2016 1:32:02 AM
Applies To | |||
Product(s): | STAAD.Pro | ||
Version(s): | ALL | ||
Environment: | ALL | ||
Area: | Analysis | ||
Subarea: | Direct Analysis | ||
Original Author: | Sye Chakraborty, Bentley Technical Support Group | ||
Are there any benchmark problems or validation examples for the Direct Analysis method implemented in STAAD?
The AISC published two benchmark problems to ascertain suitability of a second order analysis method for use in Direct analysis. These are available in the Appendix 7 Commentary section 7.3 of the AISC 360-05 specifications. STAAD.Pro direct analysis has been validated against these two benchmark problems and the results are found to be satisfactory. A pdf document with details of the two benchmark problems along with the two STAAD models used for verification, can be accessed using the link below.
Tags: Verification , direct analysis verification, Benchmark problems on Direct Analysis, Validation problems, Benchmark problems