AutoPIPE New User Guide [TN]
Soil Identifiers are Templates from Model to Model
Like Pipe Identifiers, Soil Identifiers can be a template and used over and over again in the model without having to re-define the properties. Use the new Soil and Soil ID grid to check and make changes to global soil properties quickly.
Distance Calculator as a Productive Tool
Use the graphical distance calculator to check distances and clearances between pipe to pipe or pipe to structure.
- Select Tools > Distance or click the distance icon on the View toolbar.
- Point and Click the TO and the From point. You don't have to enter the point name.
- The DX, DY, and DZ offsets as well as the straigh-line distance are displayed in the status bar:
HINT: The DX, DY, or DZ offsets can be read or copy/pasted to Excel or text file
ReferencePointtoEvaluateEquipmentLoads
UsetheInsert>Xtradata>ReferenceNodefeaturetodefinereferencepointstoevaluateloadsatvesselsorrotatingequipment.
WorksineitherGlobalorlocalcoordinatesystems.Soanytimethenozzleisataskewedangletothevesselandtheallowableloadsatthenozzlearegivenrelativetothenozzleaxisthenusethelocalcoordinateaxissystem.
Youcandefinemultiple"ReferencePoints"atanypoint.
HINT:Usefulforevaluatingin-linepumpnozzlesandmanufacturerstatedlimitsonvesselsorequipment.
ProductiveGraphicFeatures
Colors
Ifyouareexperiencingdifficultyviewingcolorplots,youcanchangecontrastinglegendson-the-fly.Simplydouble-clickanlegentcolortodynamicallychangeit.
Scale
Ifyouwishtochangethescaleofsupportsorothercomponentsforprefferedviewing,youcandosofromtheViewSettingsdialog.
RenderedSupportGraphics
ShowRealisticSupportArrangementstoClients,ContractorsorCADDesigners.
TeeTypes
QuicklycheckTeeTypesontheplotusingtheShowTeebutton.
Viewports
SwitchbetweenSingle/DoubleorQuadviewportstoeasilyworkinaviewwhichisconvenientthenswitchbacktosingleview.ViewportsareavailableforeditingthemodelANDviewingresultse.g.codestressesinplan,isoandelevationviewsasbelow:
Viewportsaresavedevenwhenamodelisclosedandthenre-opened.
Graphical Point Editing
Caesar users are used to looking at the model, then reading and entering the point name. In AutoPIPE like CAD use point and click, point names are automatically taken care of.
AutoPIPE | Caesar |
|
|
|
|
PipeStressWorkinvolveslotsofIterations
99levelsofUndo/RedoareavailableatalltimesinAutoPIPEsuchthatdifferentsupportconfigurationscanbetriedandifstressesorequipmentloadsareworsethencaneasilyrevertbacktosomepreviousstate.ButinCaesarundo/redoisalwayslostwhenexittheINPUTmodule.
Alphanumericnodenumberingbysegments-easytoidentifywhichnodesrelatetowhichparts/linenumbersofthemodel.
Comprehensive Automatic Code Combinations
VCR buttons allow fast navigation to sorted multiple maximum stresses across multiple stress categories including maximum sustained stress, thermal range and all occasionalstress combinations which Caesar does not calculate automatically.
AutoPIPE Stress Plot | Caesar Stress Plot |
Thermal case 1 to 4 | What stress case is Row 18-21? |
AutoPIPE Benefits:
|
|
AutoPIPEResultGridsprovidepowerfulfilteringandsortingofdisplacements,forces,supportloadsandstresses.
ClearComponentSymbols
JacketedPiping-UseTransparentSettingforPipe
EasilycreatetheJacketbyusingthegraphicalSelectandcopy/pastefunctions.Selecttherangeofcarrierpipeincludingvalves,flanges,reducersetcandpastingthenconnectingbackontoitself...coveredinadvancedtraining.
CommonCaesarmodelingtechniquesandequivalentinAutoPIPE
MakeGlobalChangese.g.changingcoefficientoffrictionsforpipesupports,globalchangestopressures,temperatures,materials,etc
ChangeTemperatureinModel
Caesar
UseListspreadsheet
ChangeREDvaluee.g.482to555.Thischange‘Ripples‘downtonextREDvalue.Difficulttoidentifywhichpart(s)ofthemodelhaschanged.Needtokeepswitchingonthecolortemperatureplot.Maybeotherpartsofmodeltochangeto555also,needtofindthem.
Thischangecannotbeseeninlegendnoronthecolortemperatureplotunlesstheplotisreset.
AutoPIPE
MakeGlobalchangestopressure,temperature.OptionAisbestforperformingglobalchangesacrossthewholemodel.OptionCallowsbestmethodtocheckallvaluesbeingchangedpointbypoint.
OptionA-
- SelectOperatingLoadbyValuefromtheModifymenu.
- Selecttheexistingtemperatureandenterthereplacementvalue.Thiswillreplacealltemperaturesinthewholemodel(482with555,inthisexample).
OptionB-
- Selecttherangeinthemodeltochangetemperature
- SelectPressure&TemperaturefromtheModifymenu.
- Enternewtemperature(555forthisexample).Thenewtemperatureisshowninbluetoindicatewhichvalueshavechanged.
- ClickOK.Thecolorplotandlegendareupdatedimmediatelywiththenewvalue.
OptionC-UseInputGrids
- SelectView>Show>Temperaturetoseecolortemperatureplot.
- DoubleclickCase1Tempcolumntosortit.
- Selectthecellswiththistemperature.
Enternewvalue(e.g.-555)andpressCTRL+Enter.
HINT:Dragdownorcopydowncommandsusingrightclickmenu,arealsoavailableformakingglobalchangeslikeExcel.
- TheselectedcellsimmediatelyhighlightREDontheplottoseewhichpartsofthemodelaretobechanged.
ChangeSupportFriction
Caesar
Youmushchangefrictionvaluesonebyone:
AutoPIPE
- IntheSupportGrid,doubleclickcolumntosortdata.
Selectmultiplecellsyouwishtochange.
or
SelectthecompletecolumnandthenselectonecellwhileholdingdowntheCTRLkey.
EnternewvalueinfirstcellandthenpressCTRL+Enter.
NOTE:OneCTRL+Zstepwillundothecompletechange.
UpdateMaterialLibraries
WARNING:RecommenddonotusetheTools>Libraryfunctiontoupdatelibraries
Materiallibrariesareorganisedinto2tables,table1withgenericmaterialse.g.CS,HCetcwhichonlyhavephysicalproperties(noallowablestress).Table2hasCodeSpecificationmaterialse.g.A106-B,A312-TP316whichhavetemperaturevs.allowablestressdata
NOTE:Version9.0moreexoticalloysteelslikeduplexstainless,Haynes556,incoloy825,copperC12200-B88andHastelloyC22forB31.3library.
OptionA
ProvidesourcedatatoBentleyincludingtemperaturevs.expansion&modulus,density,poissonsratio,plustemperaturevs.allowablestress(sometimesalsoyieldstress-requiredbysomecodeslikeB31.3).BentleywillcreateacustomlibrarybutnotnuclearQAtested.
OptionB
RequestthelibrarysourceforthepipingcodeyearandinstructionsfromBentley,enterowndataandrecompilethelibrary.
FRP/GRP/Plasticmaterials-refertoModelingFRPandPlasticPipinginAutoPIPE
FollowingFRPlibraryisavailableforusetypicallywithB31.3
PipePropertiesorPipeIdentifiers-templatesforcompleteproject
Materialsareselectedforeachpipeidentifierdefinedinthemodel.
PipeIdentifierscanbedefinedatthebeginningoftheprojectorjobandusedastemplatesforeachmodeli.e.thepipepropertiesincludingmaterialsdonothavetobere-definedoverandoveragain.Pickandchoosewhichpipeidentifierstobeappliedoveranyselectedrangeofpipes.
SettingtheGlobalCoordinatesforStartoftheModel
OptionA
- Inthepointgrid,gotofirstentry.
- Entertheoffsetsorglobalcoordinatesofthefirstpointinthemodel.
OptionB
- SelectModify>Pointatthefirstpointinthemodel.
- EnterstartingoffsetsfromtheOrigin(0,0,0).
Similarlyfordisconnectedorindependentpipingsystems(segments)setthestartingcoordinates.Note:Anewsegmentcaninserted(Insert>Segment)andentertheOffsetpointe.g.B10(notOfororigin)andcorrespondingoffsets.Sothenewsegmentwillbeinsertedoffsetfromaknownpointinsteadoftheorigin(O).