The KL/r value that STAAD reports for the Y axis for a single angle does not match what I get from my hand calculation

$
0
0
Current Revision posted to RAM | STAAD Wiki by Steve Crabtree on 6/15/2016 1:47:09 PM

  
 Applies To 
  
 Product(s):STAAD.Pro
 Version(s):All
 Environment: N/A
 Area: Design
 Subarea: American Steel Design
 Original Author:Bentley Technical Support Group
  

The KL/r value that STAAD reports for the Y axis for a single angle does not match what I get from my hand calculation. Can you explain why? 

For single angles, the local Y and Z axes are the principal axes as shown below:

  

The KL/r value is computed using ry and rz which are based on the principal axis system. Chances are that your handculation uses the geometric axes.