Can't Assign CCB_SP to some CBB Joints

$
0
0
Current Revision posted to RAM | STAAD Wiki by Karl G on 5/31/2016 1:25:02 PM

 Applies To 
 Product:Ram Connection
First Affected Version:11.00.00.164
 Found in Version:11.00.00.177
Fixed in Version:
Environment:All
 Area: General
Subarea:N/A
 Issue #:338403

Problem Description

When trying to assign a CBB_SP template to a CBB Joint the following error comes up;

[Error] Assignment errors for joint 1
[Information] Internal design error in the connection. Please contact technical support.

Reason

Affects RAM Connection Standalone, Ram Connection for Ram Structural System, or RAM Connection for Ram Elements. 

Solution

The problem will be corrected in the next release. Alternatively, assign a CBB_DA connection template to the joint, then change the connection to the column to be a single plate.

Tags: GENERAL, Gusset, RAM Connection, Single plate, known issue, Joint