Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 5/16/2016 8:46:54 PM
Applies To | |||
Product: | Ram Steel Column | ||
First Affected Version: | 15.00.00.00 | ||
Found in Version: | 15.00.00.00 | ||
Fixed in Version: | 15.02.00.00 | ||
Area: | Design | ||
Issue #: | 352693 |
Problem Description
Using View/Update on aingle story steel columns supported by Concrete or Other material columns causes the error message "Fy must be greater than zero".
Reason
While the designs for single story steel columns supported by Concrete or Other material columns were correctly designed, an investigation of the steel columns through the View Update process resulted in an erroneous error message: Fy must be greater than zero. Reports for the steel columns correctly indicated a non-zero Fy value.
Solution
Problem solved in version 15.02.00.00. Ignore the warning on older versions.
Tags: Column, known issue, error message, Fy, RAM Steel