Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

Fy must be greater than zero error

$
0
0
Current Revision posted to RAM | STAAD Wiki by Seth Guthrie on 5/16/2016 8:46:54 PM

 Applies To 
 Product:Ram Steel Column
First Affected Version:15.00.00.00
 Found in Version:15.00.00.00
Fixed in Version:15.02.00.00
 Area: Design
 Issue #:352693

Problem Description

Using View/Update on aingle story steel columns supported by Concrete or Other material columns causes the error message "Fy must be greater than zero".

Reason

While the designs for single story steel columns supported by Concrete or Other material columns were correctly designed, an investigation of the steel columns through the View Update process resulted in an erroneous error message: Fy must be greater than zero. Reports for the steel columns correctly indicated a non-zero Fy value.

Solution

Problem solved in version 15.02.00.00. Ignore the warning on older versions.

Tags: Column, known issue, error message, Fy, RAM Steel

Viewing all articles
Browse latest Browse all 8748

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>