Changes Cannot be Saved Because Connection is Read-Only Error

$
0
0
Revision 1 posted to Structural Analysis Wiki by Karl G on 4/19/2016 2:13:34 PM

 Applies To 
 Product(s):RAM Connection; RAM Structural System
 First Affected Version:N/A
Found in Version:N/A
Fixed in Version:
Environment:All
 Area: Modeling; Tables
 Issue Number:

Problem Description

The error below displays when attempting to save a connection:

Reason

The error occurs when connections are evaluated by editing information in the Connection Templates that are installed with the program. These templates are accessed by clicking on Home menu - Databases toolbar - Connections (see below). These are the template files that are used to design basic and smart connections. The program installed templates are not intended to be edited by the user.

Solution

Design the connection by first creating a joint (Home - Joints Toolbar - New) and then assigning a connection to the joint (Design - Assignment Toolbar - Assign). 

If you are attempting to edit the connection template, copy the connection template file to a User Group in the database and then edit the copied connection template.