Known issues in STAAD.Pro SS6

$
0
0
Revision 24 posted to Structural Analysis Wiki by Sye on 2/12/2016 12:15:35 AM

This page lists issues that has been observed in SS6 since it's release

Defect #Issue Description WorkaroundComments
 -New STAAD.Pro Editor freezing up/crashing

Addressed in 20.07.11.45
 257533Section properties for std pipes and extra strong pipes are interchanged for AISC section database

Addressed in 20.07.11.45
 257492Some newly added wide flange section names in the AISC database had spaces in them which caused the engine to crash

Addressed in 20.07.11.45
264569Inclined members are not being split through Geometry > Intersect Selected Members > Intersect1.     Open the program and go to configuration
2.     Set the base unit as English.
3.     Open the model and go to the top menu option View > Options > Tolerance
4.     Set it to 0.1 inch and click on Apply > Ok
5.     Select the members and try to intersect them by going to Geometry > Intersect Selected Members > Intersect. Enter a tolerance of 0.1 inch.
 257167The plots of Mz, My, Fy, Fx etc.in the Post Processing Mode > Beams -> Graph page are not displayed for the load cases or load combinations which include wind load generationThe diagrams can be seen in the graphics window by turning on the display icons for these items from the toolbar or one can double click on the individual members and go to the Shear Bending Tab inside the Member Query dialog box to see the diagrams.Addressed in 20.07.11.45
257528

 When multiple tapered members are designed in group with CHECK CODE ALL command vs. designed individually, the design results do not match. Noted for multiple codes like AISC /IS 800/ S16.

The only option for now is to design these tapered members individually using CHECK CODE MEMB ... command.
290989For design as per AISC 360-05 or 10 codes, the MNZ and MNY are reported as 0 in the Steel Design tab within Member Query dialog box. This is a reporting error.Add the design parameter called TRACK and set it to 1 or 2. Rerun the analysis and the MNZ and MNY should now be non-zero in the Member Query dialog box.
314845Design of angles and Tees fail as per the AISC code when seismic provisions of AISC 341 are checkedThere is currently no workaround other than commenting out the seismic checks for these sections. 

323889

STAAD.Pro is not able to read the external user table files and is generating errors like

 

*** ERROR : FILE NOT FOUND C:\...\...

**ERROR- IN READING MEMBER PROPERTIES. CHECK DATA FORMAT CAREFULLY.

Provide the full path name to the file. For example instead of specifying

 

START USER TABLE

TABLE 1 wf1.txt

END

 

specify the input as shown next

 

START USER TABLE

TABLE 1 C:\Model_folder\Model_name\wf1.txt

END

 


324630

STAAD.Pro is crashing during analysis when SELFWEIGHT is applied to a list as shown next

LOAD 1 LOADTYPE Dead 
SELFWEIGHT Y -1 LIST 1 TO 100  

Please avoid using the word LIST for now and use only SELFWEIGHT Y -1.
319346

There is an error in plotting of the axial force diagram (FX) for TRUSS members. Wedges are formed at the ends instead of a uniform plot. The values are correctly computed in the analysis.

None
329816

For tapered member design as per AISC 360-05 code, design results are coming out different when members are designed in groups vs individually

Design the tapered members individually each with its own CHECK CODE command

327465

Incorrect section modulus is being used for design of T sections when design is carried out per AISC 360 and section H2-1 is the governing criteria. The stress value reported is highly conservative.

None
290996

When the report option Output > Steel Design Detail is used to get detailed design report, the generated report is incomplete for some codes like AISC 360-05 or AISC 360-10

One can get the detailed design report ( TRACK 2 output ) printed in the analysis output file. A concise version of design report can be obtained by including the option Output > Utilization Ratio Table

357132

Some users were not able to access the STAAD News from within the startup page and also not able to connect to the Personal Portal using the Connection Client Widget.

For those users experiencing the problem the following workaround is suggested.

 

  1. Close all Bentley products.

  2. Uninstall the existing Connection Client ( from within Control Panel > Programs and Features )

  3. Download an Updated Bentley Connection Client from the following page http://communities.bentley.com/products/structural/structural_analysis___design/m/structural_analysis_and_design_gallery/271606

  4. Click on the Download button on the right to start downloading. Please note that you have to be logged in with your Bentley Login to be able to download the file.

  5. A zip file BentleyCC.zip will be downloaded. Extract the contents of the zip to any folder in your machine and you will find 3 files

    blg6410000319en.exe

    blog10000319en.exe

    ConnectClientClrWrapper.dll

  6. If you have a 64 bit OS, right click on the first exe and choose Run as Administrator to install the connection client.

  7. Alternately if you have a 32 bit OS, right click on the second exe and choose Run as Administrator to install the connection client.

  8. Copy the file ConnectClientClrWrapper.dll to the folder C:\SProV8i SS6\STAAD\ConnectClient. There will be a file by the same name in that folder. Replace it with this one.

  9. Log in to Connection Client using your Bentley login credentials.

  10. Launch STAAD.Pro and you should now be able to connect to STAAD News and also access the Personal Portal.