Revision 5 posted to Structural Analysis Wiki by Seth Guthrie on 11/16/2015 4:29:14 PM
Applies To | |||
Product(s): | RAM Connection Stand Alone | ||
Version(s): | 11.00.00.164 | ||
Area: | Modeling; Tables | ||
Original Author: | Bentley Technical Support Group | ||
Problem Description
In RAM Connection Stand Alone version 11, within the Joint Dialog for any joint type that utilizes a column or a brace, the user cannot select the desired section for the Column or Brace because only one table is available. No other groups or countries can be selected. Defect #324469
Reason
An error in the program's use of tables.
Steps to Resolve
Install Ram Connection 11.00.00.177 released November 16, 2015. Release notes here. In version 11.00.00.164 the size of the brace and column could still be changed within the Connection pad (though not saved).
Tags: Column, Brace, RAM Connection, section, tables, SELECTsupport