Modeling Continuous Fondations

$
0
0
Current Revision posted to Structural Analysis and Design - Wiki by Seth Guthrie on 9/1/2015 8:55:35 PM

  
 Applies To 
  
 Product(s):RAM Structural System
 Version(s):10.0 and later
 Area: Modeling
 Original Author:Bentley Technical Support Group
  

How can I model continuous foundations?

In RAM Structural System, a continuous foundation can be modeled under walls or columns. Like all foundations, start on the lowest framed level, it is not required to make a separate foundation level in the program. On that level place the foundation using Layout - Foundation - Continuous - Add.

When placing a continuous foundation the user must start and end the foundation at a column or wall end point. If other columns along the foundation are slightly off the center line they can still be considered in the foundation design so long as they fall within the set tolerance.

One problem is when there are too many snaps turned on. When placing continuous foundation, we suggest turning off all snap modes except columns and walls to prevent accidentally snapping to other items on the layout. 

Another problem has to do with walls that are segmented or step down. The program is limited to designing continuous foundations that start where a line of walls starts and ends where the line of walls ends. The user cannot place a foundation under part of the length of a wall, even if the wall is segmented. 

See Also

RAM SS - Foundation [FAQ]

Tags: footing, RAM Structural System, Modeling, RAM Foundation, Continuous Foundation, SELECTsupport