Problem Description
When trying to open a Ram Connection Stand-alone file version 10 (or earlier) the following errors occur:
Error: Connection "XX" does not exist"
Which will occur once for each joint in the file followed by:
Error: "Exception has been thrown by the target of an invocation"
The error may also appear in the local operating system language, e.g. in Portuguese:
Solution
Go to Control Panel - Region (or Regional Settings) and click on Additional Settings...
This opens the Customize Format dialog. On the Numbers tab, make sure that the Decimal Symbol is set to period "." and the Digit grouping symbol is set to comma ","