Are there any benchmark problems or validation examples for the Direct Analysis method implemented in STAAD ?
The AISC published two benchmark problems to ascertain suitability of a second order analysis method for use in Direct analysis. These are available in the Appendix 7 Commentary section 7.3 of the AISC 360-05 specifications. STAAD.Pro direct analysis has been validated against these two benchmark problems and the results are found to be satisfactory. A pdf document with details of the two benchmark problems along with the two STAAD models used for verification, can be accessed using the link below.
Tags: Benchmark problems on Direct Analysis, Validation problems, Benchmark problems