Browse latest Browse all 8748

Ram Steel Column Design All crashes

$
0
0
Current Revision posted to Structural Analysis and Design - Wiki by Karl G on 3/16/2015 6:19:13 PM

 Product(s):RAM Structural System; Ram Steel Column
 Version(s):14.06.02.00
 Environment: N/A
 Area: Design
 Original Author:Bentley Technical Support Group

Defect Description

When performing Process - Design All in the Ram Steel Column module in version 14.06.02.00 (x32 or x64) a crash may occur part way through the process:

Steps to Reproduce

The problem occurs in the base plate design process for columns that set upon the slab with no beam or column or wall below. It only happens in version 14.06.02.00 not prior versions. The defect was corrected in version 14.07.00.05.

Avoidance

Add a beam below the columns that do not align to columns or walls below.

Tip - Use the Options - Reference Layouts Types so that you can see the column above while modeling beams on the level below.

The problem is also corrected in version 14.07.00.05.

Tags: Column, RAM Structural System, crash, Transfer, SELECTsupport, RAM Steel