Change Reaction Mark TN

$
0
0
Current Revision posted to Structural Analysis and Design - Wiki by Steve Crabtree on 3/9/2015 3:43:40 PM

  
 Applies To 
  
 Product(s):RAM Revit Link
 Version(s):ALL
 Environment: N/A
 Area: Import/Export
 Original Author:

Steve Crabtree
Bentley Technical Support Group

  

 

 

 

 

 

 

 

 

Change Reaction Mark TN

To change the reaction mark so that there are no trailing zeros and a small "k" instead of kips you need to edit the tag family.

  • Select a start reaction tag.
      
  • Click the Edit Family button.
  • In the Family Editor select the label and click the Edit Label button.
  • Select a parameter and click the Edit Parameter's Units Format button.
  • Uncheck Use project settings.

  • Leave units set as Kips.
  • Change Rounding to 0 decimal places.
  • Set Unit Symbol to None.
  • Check Suppress trailing 0's.
  • Click OK.
  • In the Suffix column enter a lowercase k.
  • In the Edit Label dialog repeat this for each parameter as needed.
  • Click Apply and then  OK.

Back in the Revit model open the Annotation family and reload the Structural Framing Tag-w-Start Reactions. Repeat these steps for the Structural Framing Tag-w-End Reactions label.  