STAAD.foundation features | Version 5.0 | Version 4.x | Version 3.5 |
General foundations | |||
1. Isolated | X | X | X |
2. Combined | X | X | |
3. Mat foundation | X | X | X |
4. Pile Cap | X | X | X |
5. Octagonal footing | X | X | |
Plant specific foundations | |||
1. Vertical vessel foundation | X | X | |
a. Automatic pedestal size calculation based on anchor bolt arrangement | X | ||
b. Simplified seismic load generation | X | ||
c. Options to design foundation as “Square” or “octagonal” | X | ||
d. Pedestal design based on PIP | X | X | |
2. Heat exchanger foundation | X | X | |
STAAD.Pro interoperability | X | X | X |
Foundation toolkit mode | |||
1. Block/Isolated | X | ||
2. Pile Cap | X | ||
3. Combined | X | ||
4. Deadman anchor | X | ||
5. Drilled pier | X | ||
Design codes | |||
1. US (ACI 2005) | X | X | X |
2. British (BS-8110-2000) | X | X | X |
3. Indian (IS -456-2000) | X | X | X |
4. Australian (AS-3600-01- AMND 2004) | X | ||
5. Canadian (CS A23.3-04) | X | ||
Drawing Output | |||
1. General Arrangement (GA) drawing | X | ||
2. Enhanced detail drawing | X | ||
3. Footing schedule drawing | X | ||
4. Mat slab detail drawing | X | ||
5. Footing grouping and schematic diagram | X | ||
Design Enhancements | |||
1. Design for top reinforcement | X | ||
2. Check for buoyancy | X | ||
3. Cohesion (adhesion) effect in uplift | X | ||
4. Enhanced and reformatted calculation sheets | X | ||
Load combination | |||
1. Load combination generation | X | X | |
2. Process Industry Practices (PIP) load combination table | X | ||
Units | |||
1. Supports both Metric (“SI”) and English | X | X | X |
2. unit system | X | ||
3. Save Default units for “English” or “SI” unit system | X | ||
4. Reset Unit System option | X | ||
Mat foundation | |||
1. Mat foundation can be of any shape and size | X | X | X |
2. Physical slab | X | X | X |
3. Physical loads like a. Quadrilateral load b. Circular load c. Line load | X | X | X |
4. Rectangular mat foundation wizard | X | X | X |
5. Physical tie beam | X | X | X |
6. Mat foundation reinforcement zoning, block, detailing | X | P | X |
7. Mat slab capacity check for given reinforcement arrangement | X | X | |
Contours | |||
1. Reinforcement | X | X | X |
2. Base Pressure | X | X | X |
3. Plate stress including global Mx and Mz | X | X | X |
4. Beam Stress | X | X | X |
Design for biaxial moments for all foundation types including “Isolated” and “Combined”. | X | X | X |
Shear force and bending moment diagram for combined, strip and heat exchanger foundation | X | X | |
Verification manual | X | ||
Tutorials video | X | X | X |
Same footings can be designed as different foundation types to compare for suitable arrangement | X | X | X |
Revision history | X | X | X |
STAAD.foundation news feed | X |
Current Revision posted to Structural Analysis and Design - Wiki by Sye on 2/28/2015 8:46:59 AM
Tags: STAADfoundation, foundation, STAAD