Problem Description
When the ‘Precede’ program is started with a new model, if you try to ‘add a joint’ no ‘dialog box’ pops up; the same applies when one wants to add a member no ‘dialog box’ opens upon selection the ‘add a member’ function.
Reason
This issue happens when a user changes from a double monitor system to a single monitor system.
Steps to Resolve
Precede stores the last location of the dialog and if it was on the second screen it will have issues on a single screen.
You will need to reset the dialog default location. Open Precede, then select the "Precede Settings" and then check the "Reset dialog boxes to default locations" checkbox.