Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

Dialog boxes are not shown upon adding a joint/member in Precede

$
0
0
Revision 1 posted to Structural Analysis and Design - Wiki by Payel on 2/24/2015 12:38:03 AM

  
 Applies To 
  
 Product(s):Precede
 Version(s):6.1
 Environment: N/A
 Area: General
 Original Author:Payel Sasmal, Bentley Technical Support Group
  

Problem Description

When the ‘Precede’ program is started with a new model, if you try to ‘add a joint’ no ‘dialog box’ pops up; the same applies when one wants to add a member no ‘dialog box’ opens upon selection the ‘add a member’ function.

Reason

This issue happens when a user changes from a double monitor system to a single monitor system.

Steps to Resolve

Precede stores the last location of the dialog and if it was on the second screen it will have issues on a single screen.

You will need to reset the dialog default location. Open Precede, then select the "Precede Settings" and then check the "Reset dialog boxes to default locations" checkbox.

Tags: Dialog Box, add a joint, add a member, Precede