Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

Ram Steel Column Design All crashes

$
0
0
Current Revision posted to Structural Analysis and Design - Wiki by Seth Guthrie on 12/11/2014 11:39:31 PM

 Product(s):RAM Structural System; Ram Steel Column
 Version(s):14.06.02.00
 Environment: N/A
 Area: Design
 Original Author:Bentley Technical Support Group

Defect Description

When performing Process - Design All in the Ram Steel Column module in version 14.06.02.00 (x32 or x64) a crash may occur part way through the process:

Steps to Reproduce

The problem occurs in the base plate design process for columns that set upon the slab with no beam or column or wall below. It only happens in version 14.06.02.00 not prior versions. The defect is being investigated and a fix should be released in version 14.07.00.00.

Avoidance

Add a beam below the columns that do not align to columns or walls below.

Tip - Use the Options - Reference Layouts Types so that you can see the column above while modeling beams on the level below.

Tags: Column, RAM Structural System, crash, SELECTsupport, RAM Steel

Viewing all articles
Browse latest Browse all 8748

Trending Articles



<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>