Quantcast
Channel: RAM | STAAD | ADINA Wiki
Viewing all articles
Browse latest Browse all 8748

Cannot Save Model in RAM Modeler

$
0
0
Current Revision posted to Structural Analysis and Design - Wiki by Seth Guthrie on 11/19/2014 11:59:39 PM

 Product(s):RAM Modeler
 Version(s):14.06.01.00
 Environment: N/A
 Area: File
 Original Author:Bentley Technical Support Group

Problem Description

When attempting to save a file in RAM Modeler, an error like the one below occurs:

"Could not zip ram model files: P:\ to create file P:\filename.rss.  Please contact Bentley Technical Support."

The drive specified is a network drive. The actual file may be saved either locally or on the network drive.

Reason

The working directory is set to a network drive. The program is prevented from compressing the files in the working directory into the .rss file format after using the save command.

Steps to Resolve

Option 1: Save the Model in RAM Manager

The problem with saving the file in the working directory does not occur in RAM Manager.

Option 2:  Change the Path of the working directory

Refer to the first frequently asked question on the following web page for information on changing the path of the working directory:

RAM SS Files FAQ

The default path are:

Windows Vista/7 - C:\ProgramData\Bentley\Engineering\RAM Structural System

Windows XP - C:\Documents and Settings\All Users\Application Data\Bentley\Engineering\RAM Structural System

See Also

RAM SS Files FAQ

Structural Product TechNotes and FAQs

Tags: error, working directory, Support Solutions, Network, RAM Modeler, save