Error designing one or more section cuts.

$
0
0
Revision 3 posted to Structural Analysis and Design - Wiki by Seth Guthrie on 11/19/2014 11:55:46 PM

  
 Applies To 
  
 Product(s):RAM Concrere Shear Wall
 Version(s):Any
 Environment: N/A
 Area: Design
 Subarea: 
 Original Author:Bentley Technical Support Group
  

Problem Description

The error message "There has been an error designing one or more section cuts. Internal error designing cut(s)" is displayed during the design of one or more wall design groups in RAM Concrete Shear Wall.

Steps to Resolve

This error may be associated with very short wall segments (6" or less) as shown below:

 

To resolve the problem, delete the small wall segments and then delete and remodel the section cuts when returning to RAM Concrete Shear Wall.

Tags: RAM Structural System, Support Solutions, Ram Concrete, Shear Wall