Current Revision posted to Structural Analysis and Design - Wiki by Seth Guthrie on 11/19/2014 11:51:55 PM
Product(s): | RAM Concrete | ||
Version(s): | Any | ||
Environment: | N/A | ||
Area: | Analysis | ||
Original Author: | Bentley Technical Support Group |
Problem Description
A blank Analyze Error dialog is displayed when running the RAM Concrete Analysis:
Reason
The error is associated with corrupt settings in the Analysis Criteria dialog. See below. Common examples of bad settings include:
1. No solver selected.
2. Values of 0 for mesh parameters: Merge Node Tolerance, Max Distance Allowed Between Nodes, and Geometry Tolerance.
3. Large value for Minimum Number of Stations per Beam.
4. No Rigid End Zone option selected.
5. No Beam Torsion Stiffness option selected
Steps to Resolve
Redefine the settings with appropriate values. The program installed defaults can be found here:
Tags: analysis, Criteria, RAM Structural System, Analyze Error, Support Solutions, Ram Concrete